Pressure Range * 10 Pa up to 7500 Pa * Linear Pressure Display in Pa * Adjustable to kPa - mBar * Range adjustable +/- 50% of range
Air Volume Range * Linear volume Display selectable via Keyboard * m/s - m3/s - m3/h - l/s - ACR (Air Change Rate) * Small value display shut off function at no flow
Signal Output * 0...10V and 4..20mA * Output programmable i.e 1..5V - 5..19mA * PID control output programmable * Pressure or Velocity output
Alarm Output * 2 Relay Volt free change over contacts 24dc/ac non inductive *1 Digital Input for mute alarm or door contact . 1 Analogue Input for set point or feed back of actuator Linearity 0.25% of Full Scale => 100 Pa and 0.25 Pa <100 Pa Overload protection programmable on/off Power Supply 24Vac/dc (100mA) non isolated Power Supply 24Vac isolated Repeatability 0.1% of Full Scale Temperature drift 0% with auto zero selected 'on' Temperature drift 0.05%K(+10C to 50C) with auto zero selected 'off' Enclosure Plastic IP44 Tube connection 4mm barbed or 6mm barbed Two Modbus rtu communication ports standard Remote Display connects to Modbus port 2 including power supply Terminal connections on rear Calibration mode adjustment
* DPM-120 Panel Sensor Pressure - Volume Transmitter * Seven Segment LED display * Operator Keyboard with alarm indicators amber-amber * Ranges from 10 Pa up to 7500 Pa * Linear Pressure Display in Pa standard. * Adjustable to kPa - mBar * Range adjustable +/- 50% of range via keyboard * Linear volume Display selectable via Keyboard. * m/s - m3/s - m3/h - l/s - ACR (Air Change Rate) * Small value display shut off function at no flow. * Signal Output : 0...10V and 4..20mA * Output Keyboard programmable i.e 1..5V - 5..19mA * PID control loop output on selectable terminal * Pressure or Velocity output on selectable terminal * Calibration mode adjustment * 2 Calibration valves * Adjustable alarm threshold indicated by red-amber-green LED * 2 Relay Volt free change over contacts 24dc/ac non inductive * 1 Digital Input for mute alarm or door contact. * 1 Analogue Input for set point or feed back of actuator. * Linearity 0.25% of Full Scale => 100 Pa and 0.25 Pa <100 Pa * Overload protection programmable on/off * Power Supply 24Vac/dc (100mA) non isolated * Power Supply 24Vac isolated * Repeatability 0.1% of Full Scale * Temperature drift 0% with auto zero selected 'on' * Temperature drift 0.05%K(+10C to 50C) with auto zero selected 'off' * Enclosure Plastic IP44 * Tube connection 4mm barbed or 6mm barbed * Two Modbus rtu communication ports standard * Remote Display connects to Modbus port 2 inclding power supply * Terminal connections on rear * UKAS traceable Calibration Certificate is standard
* DPM-120 Panel Sensor Pressure - Volume Transmitter * Seven Segment LED display * Operator Keyboard with alarm indicators amber-amber * Ranges from 10 Pa up to 7500 Pa * Linear Pressure Display in Pa standard. * Adjustable to kPa - mBar * Range adjustable +/- 50% of range via keyboard * Linear volume Display selectable via Keyboard. * m/s - m3/s - m3/h - l/s - ACR (Air Change Rate) * Small value display shut off function at no flow. * Signal Output : 0...10V and 4..20mA * Output Keyboard programmable i.e 1..5V - 5..19mA * PID control loop output on selectable terminal * Pressure or Velocity output on selectable terminal * Calibration mode adjustment * 2 Triacs for Tri Control of actuator 24ac. * Adjustable alarm threshold indicated by red-amber-green LED * 2 Relay Volt free change over contacts 24dc/ac non inductive * 1 Digital Input for mute alarm or door contact. * 1 Analogue Input for set point or feed back of actuator. * Linearity 0.25% of Full Scale => 100 Pa and 0.25 Pa <100 Pa * Overload protection programmable on/off * Power Supply 24Vac/dc (100mA) non isolated * Power Supply 24Vac isolated * Repeatability 0.1% of Full Scale * Temperature drift 0% with auto zero selected 'on' * Temperature drift 0.05%K(+10C to 50C) with auto zero selected 'off' * Enclosure Plastic IP44 * Tube connection 4mm barbed or 6mm barbed * Two Modbus rtu communication ports standard * Remote Display connects to Modbus port 2 inclding power supply * Terminal connections on rear * UKAS traceable Calibration Certificate is standard